MILPRF19500/572C
TABLE I. Group A inspection Continued.
Limits
Inspection 1/
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 3 Continued
TA = 55°C
Low temperature:
µA dc
Reverse current
4016
DC method; VR = 3 V dc
IR
1.0
Forward voltage
4011
DC method
VF
1N6493, 1N6494
IF = 20 mA dc
3.25
V dc
1N6500, 1N6501
1N6495, 1N6502
3.25
V dc
IF = 25 mA dc
Subgroup 4
Capacitance
4001
VR = 0; f = 1 MHz
C
100
pF
Subgroups 5, 6, and 7
Not applicable
1/ For sampling plans, see MILPRF19500.
8