MILPRF19500/519E
TABLE II. Group A inspection for panel mount assemblies.
Limits
Symbol
Unit
Inspection 1/
Method
Conditions
Min
Max
Subgroup 1
External visual
2071
examination
Subgroup 2
Luminous intensity
2/ 3.0
mcd
IV1
3/ 20.0
mcd
IF = 20 mA dc
Θ = 30 degrees; IF = 20 mA dc
Luminous intensity 2/
1.5
mcd
IV2
µA dc
Reverse current
4016
1.0
DC method; VR = 3 V dc
IR
Forward voltage
4011
3.0
V dc
DC method, IF = 20 mA dc
VF
Subgroup 3, 4, 5, and 6
Not applicable
Subgroup 7
Solderability 4/
2026
15 devices, c = 0
Resistance to solvents
1022
15 devices, c = 0
Physical dimensions
2066
See figure 2, 45 devices, c = 0
1/
For sampling plan, see MILPRF19500.
2/
Applies to JAN19500/51901 and JANTX19500/51902.
3/
Applies to JANM19500/51903 and JANTX19500/51904.
4/
The sample size for solderability test applies to the number of leads inspected except in no case shall less than
three leads be used to provide the number of leads required.