MIL-PRF-19500/486H
TABLE I. Group A inspection - Continued.
MIL-STD-750
Limit
Symbol
Unit
Inspection 1/ 2/
Method
Conditions
Min
Max
Subgroup 3 - Continued.
TA = -55°C
Low temperature operation
Coupler characteristics
VCE = 5 V dc, IF = 10 mA dc
IC(ON)4
On-state collector current,
3041
phototransistor mode:
(see 4.5.6)
4N22, 4N22A, 4N22U
1.0
mA dc
4N23, 4N23A, 4N23U
2.5
mA dc
4N24, 4N24A, 4N24U
4.0
mA dc
LED characteristics:
IF = 10 mA dc (see 4.5.3)
VF3
Forward voltage
4011
0.9
1.7
V dc
Subgroup 4
f = 1 MHz, (see 4.5.5), |VIN-OUT| = 0
CIO
Input to output
5
pF
capacitance
Ω
|VIN-OUT| = 1 kV dc (see 4.5.5)
RIO
1011
Input to output internal
1016
resistance
VCC = 10 V dc, IF = 5 mA dc,
tr
Rise time
phototransistor mode:
RL = 100 ohms (see figure 3)
µs
4N22, 4N22A, 4N22U
15
µs
4N23, 4N23A, 4N23U
15
µs
4N24, 4N24A, 4N24U
20
VCC = 10 V dc, IF = 5mA dc,
tf
Fall time
phototransistor mode:
RL = 100 ohms (see figure 3)
µs
4N22, 4N22A, 4N22U
15
µs
4N23, 4N23A, 4N23U
15
µs
4N24, 4N24A, 4N24U
20
Subgroups 5 and 6
Not applicable
Subgroups 7
Monitored thermal shock
See 4.3.1.1
(temperature cycling)
1/ For sampling plan, see MIL-PRF-19500.
2/ All devices required by the specified sampling plan are subjected to subgroups 2, 3, and 4 combined (JANS only).
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.