MILPRF19500/521E
TABLE I. Group A inspection.
Limits
Symbol
Unit
Inspection 1/
Method
Conditions
Min
Max
Subgroup 1
Visual and mechanical
2071
examination
Subgroup 2
Luminous intensity
2/ 3.0
mcd
IV1
3/ 20.0
mcd
IF = 20 mA dc
Luminous intensity 2/
1.5
mcd
IV2
Θ = 30 degrees; IF = 20 mA dc
Reverse current
4016
1.0
DC method; VR = 3 V dc
IR
µA dc
Forward voltage
4011
3.0
V dc
DC method, IF = 20 mA dc
VF
Subgroup 3
High temperature
TA = +100°C
operation:
Reverse current
4016
1.0
DC method; VR = 3 V dc
IR
µA dc
Forward voltage
4011
3.0
V dc
DC method, IF = 20 mA dc
VF
Low temperature
TA = 55°C
operation:
Reverse current
4016
1.0
DC method; VR = 3 V dc
IR
µA dc
Forward voltage
4011
3.0
V dc
DC method, IF = 20 mA dc
VF
Subgroup 4
Capacitance
4001
C
100
pF
VR = 0; f = 1 MHz
Subgroups 5, 6, and 7
Not applicable
1/
For sampling plan, see MILPRF19500.
2/
Applies to JAN1N6094 and JANTX1N6094.
3/
Applies to JAN1N6611 and JANTX1N6611.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business